CG170-20 Gas Generator Set

.
🔍

 

Technical Specifications
Benefits and Features
Equipment
Generator Set Specifications
Continuous Rating 2000 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas
Maximum Electrical Efficiency 43.70%
Maximum Standby Rating 2000
Frequency 50 / 60 Hz
RPM 1500
Engine Specifications
Engine Model CG170-20
Displacement 3240 in³
Aspiration TA
Bore 6.7 in
Stroke 7.7 in
Generator Set Dimensions
Length 294 in
Width 67 in
Height 86 in
Dry Weight - Genset 43651.1 lb

High Efficiency, Lower Operating Costs

  • Miller cycle timing with combustion chamber and spark plug improvement help on saving up to 15% fuel gas per year
  • CG170 (non-miller) is optimized for Island-Mode capability
  • Gearbox helps limit wear and tear on engine components, lowering operating costs and increasing availability

Low installation, Building and Operating Costs

  • Extended maintenance intervals thanks to sooth-free combustion and enlarged oil tank
  • Low fuel consumption due to improved combustion chamber and pre-chamber spark-plugs
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
  • Optimized oil management

Optimized Lubrication Consumption

  • Consumes up to 1900 liter less lube oil per year than comparable models<li>
  • Longer lubricant change and oil change intervals<li>

Standard Equipment:

  • Air Inlet
    • Turbocharger with a water-cooled bearing case for all cylinder
    • One-element single-stage air cleaner with enclosure and sevice indicator
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • Jacket water and SCAC thermostats
    • flange connections for JW inlet and outlet
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
    • Exhaust waste gate for the CG170-20
  • Fuel System
    • Pre-chamber spark plugs
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
  • Generator
    • Winding temperature detectors
    • 3-phase sensing and KVAR/PF control
    • Reactive droop
    • closed-coupled generator result in no torque transmission to the base frame
    • grid code generator
    • Anti-condensation space heater
    • Busbar connections
  • Starting/charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard

Optional Equipment:

  • Cooling
    • CHP skid
  • Grid Code Compliance
    • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands


Related Equipment


EASY TO UPDATE. WORK LIGHTS USE PROMO CODE LIGHTS30

X